Oscilloscope hdo6034a sweep setting
WebJul 7, 2016 · The small multipurpose knob at the top center of the front panel permits adjustment of the amount (time interval) of hold-off, and the present setting is shown. … Websensitivities (volts/div), sweep time (sec/div) and trigger settings are shown along the bottom of screen: channel 1 (\Ch1 1V") is showing a 2 volt peak-to-peak sine wave, and channel 2 (\Ch2 5V") is showing a 0 to 5 volt square wave. The sweep time is 500 s/div (\M 500 s"), and the trigger is set for a 20 mV positive-going level in channel 1.
Oscilloscope hdo6034a sweep setting
Did you know?
WebHorizontally, there are ten divisions, each with a setting of 100us/div, for a total of 1000us, or 1ms. This is exactly the period of a 1KHz sine wave. Figure 1 – Scope capture of a … WebAug 27, 2024 · Setting up the oscilloscope is the first skill that any technician needs to master – it is essential that the displayed waveform can be analysed quickly and accurately. To test the sensor the technician could use channel A for the supply Voltage and Channel B for the Camshaft sensor signal – the sensor ground once tested can be used as the ...
WebTeledyne LeCroy HDO6034A Oscilloscope (350 MHz, 4 Input Channels, 50 Mpts/ch, 10 GS/s) Key Features ±10 V applied offset with high gain settings MAUI with OneTouch … WebJul 10, 2024 · Name the new simulation AC_Sweep and click Create. In Analysis Type, select AC Sweep/Noise. Set the Start Frequency to 10. Set the End Frequency to 100MEG. Set Points/Decade to 11. Click OK. Select PSpice > Run from the menu. In the Plot Window, select Trace > Add Trace from the menu. In Simulation Output Variables, select …
WebTeledyne LeCroy WebThe seconds-per-division setting (usually written as sec/div) lets you select the rate at which the waveform is drawn across the screen (also known as the time base setting or …
WebThe horizontal sweep rate depends upon an internal oscillator (actually, a ramp generator of variable frequency) and the internal horizontal deflection amplifiers. The time base calibration may be checked by connecting a BNC cable with leads or an oscilloscope probe from the 1.0 kHz output (PROBE COMP ≈ 5V)
WebHDO6034A-MS. The HDO6034A-MS from Teledyne LeCroy is a Oscilloscope with Bandwidth 350 MHz, Sample Rate 10 to 125 GSPS, Supply Voltage 100 to 240 VAC. … olde wayside innWebDec 4, 2016 · You can put a pot between +/- 12V sources. Connect the wiper to the amplifier input. Keep in mind the change in source resistance when you do this. Also you probably … my own vet dixie animalWebBy pressing the AUTO button you enable Connect-and-View. At this point you should see a trace that 1) lies within the vertical range of the display, 2) shows at least three periods of … my own version of you bob dylan meaningWebHigh Definition, Touch Screen Oscilloscope HDO6034A. HDO6000A oscilloscopes have 4 analog input channels, 12-bit resolution using Teledyne LeCroy’s HD4096 high definition … my own version of you dylanWebNov 8, 2024 · Notice that the scope is in a WAIT state (green text, top left corner), as it is waiting to trigger and display a signal. In Auto mode, however, the oscilloscope will … my own vet moorooka phone numberWebQuite simply, an oscilloscope is a diagnostic instrument that draws a graph of an electrical signal. This simple graph can tell you many things about a signal, such as: The time and voltage values of a signal. The frequency of an oscillating signal. The "moving parts" of a circuit represented by the signal. olde west gun \u0026 loan redding cahttp://manuals.chudov.com/Tektronix_Oscilloscope_Use/exercises.pdf my own version of you lyrics dylan